background image

FDY

The Interface Solution Experts

PC-Programmable Frequency
Transmitter and Display

Specifi cations and information subject to change without notice.

Performance

Display

Ambient

Conditions

Weight

Performance

(Continued)

Specifi cations

Input Accuracy:

 

See Tables 2-7

Output Accuracy:

 ±0.015% 

of span

Overall Accuracy: 

The 

overall accuracy of the unit 
is the combined input and 
output accuracies. It includes 
the combined effects 
of linearity, hysteresis, 
repeatability and adjustment 
resolution. Does not include 
ambient temperature effect.

Input Hysteresis:

 

See Tables 5-7

Input Threshold:

 

See Tables 5-7

Stability:

 See Table 1

Minimum Frequency:

 Twice 

the lower range

Digital Input Filter:

 

3dB point is at 10kHz

Step Response Time: 

300msec maximum, 
200msec typical from the 
time an input is applied to 
the output reaching 90% of 
its fi nal value + actual input

Rise Time:

 100msec 

maximum for the output to 
change from 10% to 90% 
of its scale of an input step 
change of 0% to 100% + 
actual input

Isolation: 

500Vrms 

between input, output, 
and case continuous, and 
will withstand a 500 Vac 
dielectric strength test 
for one minute with no 
breakdown

Ripple:

 10mV peak-to-peak 

measured across a 250 ohm 
resistor

Overcurrent Limiting:

 

25mA maximum

Maximum Voltages:

 48Vdc 

output, maximum; DC 
input, 48Vdc, maximum; AC 
input, 30Vac maximum for 
0.02-30AC model, 250Vac 
maximum for 10-250AC 
model

Input Impedance:

 

>30kohms for DC and 
contact closure inputs; 
2kohms for input >6V, 
4kohms typical@50Hz and 
56kohms typical@1kHz for 
input <6V for 
0.02-30AC model; 
>125kohms for 10-250AC 
model

Load Capability:

 

(508 ohms@24V)

Output Current Limiting: 

3.8mA and 21.4mA for 
input under range and over 
range; 3.6mA and 23.6mA 
for input failure

Load Effect (current 
outputs):

 Negligible within 

specifi ed power limits

Power Supply Effect:

 

±0.002% of span per 1V 
change

Startup Time:

 Performance 

within specifi cation less 
than 1sec after power is 
applied for frequency higher 
than 100Hz and average of 
8 samples

Damping:

  Adjustable from 

0 to 30 seconds with PC 
software

Linearization:

 Confi gurable 

up to 128 points with PC 
software

Moving Average:

 

Confi gurable up to 16 
segments with PC software 

Low Pass Filter:

 

On/Off is software 
confi gurable

Type:

  LCD; Top Row, 

10.16mm (0.4 in) high 
black digits on a refl ective 
background; Bottom Row, 
5.72mm (0.225 in) high 
black digits on a refl ective 
background

Display Update Rate:

 

100msec

Format:

 Top row is fi ve 

alphanumeric characters, 
plus sign and decimal 
point; bottom is fi ve 
alphanumeric characters

Range:

 -99999 to 99999

Minimum Display Span:

 

1.00

Operating & Storage 
Range:

 

-40 to +85°C 
(-40°F to +185°F);

I.S. Operating Range:

 

-40° to +65°C 
(-40°F to +149°F);

Relative Humidity:

 

0-95%, non-condensing

Ambient Temperature 
Effect:

 Input to output, 

±0.007% of span/°C 
maximum; Digital 
Accuracy, ±0.003% of 
span/°C maximum

RFI/EMI Immunity:

 

30V/m when tested 
according to SAMA 33.1 
abc with 0.5% of span or 
less error. 20V/m@ 
80-1000MHz, 1kHz AM, 
when tested according to 
IEC1000-4-3-1995

Noise Rejection:

 

Common mode, 120dB 
typical@100mVp-p input 

FDY HP: 

227g (5.3 oz)

FDY in BH housing with 
glass cover:

 1.45kg

(3 lbs, 12.4 oz)

FDY in D-BOX housing: 

811g (1 lb, 6.3 oz)

Supply Voltage  -  12V

0.0236A

= Ohms

Содержание FDY

Страница 1: ...FDY FDYNovember 2013 165 730 00E1 PC Programmable Frequency Transmitter and Display PC Programmable Frequency Transmitter and Display...

Страница 2: ...ters 9 Programming the Input Parameters 9 Programming the Range Parameters 10 Programming the Output Parameters 11 Programming the Trimming Parameters 12 Sensor Trimming 12 Output Trimming 13 Loop Tes...

Страница 3: ...eatures a large integral display that shows real time process status About this Manual Wherever you see a Note Caution or WARNING pay particular attention A Note provides information to help you in av...

Страница 4: ...kohms typical 1kHz for input 6V for 0 02 30AC model 125kohms for 10 250AC model Load Capability 508 ohms 24V Output Current Limiting 3 8mA and 21 4mA for input under range and over range 3 6mA and 23...

Страница 5: ...Hz Table 6 Period Input Parameters Resolution 1mV 1mV 1mV Range 0 01 1 5V 0 002 0 15V 0 002 0 15V Hysteresis Measured Period 40 sec to 50sec 40 sec to 2sec 40 sec to 2sec Input Range 100mV 30V DC Reso...

Страница 6: ...3 25 in 62mm 2 45 in 64mm 2 50 in 66mm 2 58 in 76mm 3 00 in 43mm 1 70 in 18mm 0 70 in FDY COM PS 0 PS 0 6027 8 HZ Figure 2 FDY Dimensions 65mm 2 55 in GND GND 1 2 NPT 1 2 NPT 102mm 4 00 in 129mm 5 06...

Страница 7: ...rrent configuration of the attached FDY 4 Measurement Mode The drop down menu selects which type of measurement the FDY will monitor 5 Variables Device Status Communications These sections display the...

Страница 8: ...ion Program 1 2 3 4 5 6 7 Default Factory Configurations The following are the default factory settings for your unit Input Measurement Mode Frequency 0 100Hz Input Hysteresis 10mV Timeout Period 10s...

Страница 9: ...ions Cable Communications Software Programming the FDY All operating parameters of the FDY are set using a PC a serial communication cable and Moore Industries Intelligent PC Configuration software Wh...

Страница 10: ...ed to set this to the default setting of 2V maximum is 2 5V For input voltages below 3V it is recommended to set this to 2 3 of the peak to peak p p input signal voltage plus the low state signal volt...

Страница 11: ...ed reading This can be used to compensate for bent blades in a monitored turbine by setting the value to equal the number of blades on the turbine i e if the turbine has four blades set the Averaging...

Страница 12: ...ox This reduces the effect of sudden spikes and helps stop unnecessary alarms by smoothing the reading Failure Mode Failure Mode lets you set the output of the transmitter when it is malfunctioning It...

Страница 13: ...attempt to trim the FDY ensure that the correct sensor is attached to the transmitter then go to the Trimming tab as shown at the left and 1 Select the User radio button under Trim Mode then answer Y...

Страница 14: ...e output will no longer be fixed at 4mA 4 Continue by clicking the Fix Current High button This should cause the FDY to output 20mA If the output is a different value enter it into the Output Current...

Страница 15: ...int of the transmitter and the transmitter will send out a 4mA signal or the selected output signal if the zero output is set at a value other than 4mA when this point is reached Likewise the point yo...

Страница 16: ...onfiguration program you are ready to download the configuration file Downloading the Configuration File After the configuration has been set to your satisfaction it can be downloaded to the unit by s...

Страница 17: ...signal wiring should be 2 inches Note Some of Moore Industries instruments can be classified as receivers IPT2 IPX2 etc and some can be classified as transmitters TRX TRY etc while some are both a rec...

Страница 18: ...eas requiring intrinsically safe instrumentation Refer to the Special Conditions outlined below before proceeding with installation Special Conditions of Use The following instructions must be adhered...

Страница 19: ...The Interface Solution Experts 19 FDY PC Programmable Frequency Transmitter and Display...