The Interface Solution Experts
31
SPA
Site-Programmable RTD &
Thermocouple Limit Alarm Trips
Table 4. SPA LCD Error Codes
Error Codes
Every SPA is subjected to an exhaustive battery of
operational checks and tests prior to its shipment. Oc-
casionally, however, units can sustain damage getting
from the factory to the user.
As a safeguard, the unit is equipped with a full set of
internal diagnostics that check operation and con-
figuration on power-up. If there are problems with the
microprocessor, or with conflicting operating parameter
settings, the LCD will show an error code upon unit
start-up.
Table 4 lists the error codes.
For most of these problems, it will be necessary to
return the offending SPA to the factory.
EE FLT
RAM ERR
ROM ERR
CAL ERR
DATA ERR
PACT ERR
CONF ERR
RJC OPEN
TABL ERR
EEPROM Error - The internal processor failed
RAM(memory) Error - The internal processor failed
Calibration Error - The factory-set calibration of the
unit has failed to initialize.
Data Error - There are conflicts in the settings
entered into unit memory. This can be caused by
power loss or fluctuation during power-up.
Memory Packet Failure - Internal memory failure
Data Error - There are conflicts in the settings
entered into unit memory. This can be caused by
power loss or fluctuation during power-up.
Reference Junction Compensation Resistor Burnout.
Internal Table Error - The linearization curve pro-
gramming is not correct.
Cycle power to the unit, then run through the
configuration menus to ensure that the technician
made the correct sensor selections for the range
settings, etc.
Cycle power to the unit, and if the error occurs
again, return the unit to the factory for service.
Cycle power to the unit, and if the error occurs
again, return the unit to the factory for service.
Cycle power to the unit, and if the error occurs
again, return the unit to the factory for service.
Make sure that the endpoints of the programmed
curve are within the selected INPUT SCALING.
Cycle power to the unit, then run through the
configuration menus to ensure that the technician
made the correct sensor selections for the range
settings, etc.
Customer Service
If service assistance is ever required for one of the
SPAs in your application, refer to the inside of the
back cover of this manual for the telephone numbers
to Moore Industries STAR Center customer service
department.
If possible, make a note of the model number of the
offending unit before calling. For fastest assistance, try
to gather information on the unit(s) serial number and
the job and purchase order number under which it was
shipped.
Error Message
What it Means
What to Do