41
Rev. 1.0
0006302011
SSM24C User Manual
+86-400-820-9661
Faults
Position Error
the drive exceeded the position fault limit as set by the PF (Position
Fault) command
Drive Overtemperature
the DSP temperature exceeded 95 C or the drive internal PCB
exceeded 85
℃
Over Voltage
the DC bus voltage exceeded 75 VDC
Internal Voltage
one of the internal power supplies exceeded its range limit
Motor Short
a motor phase experienced a short circuit condition
Open Winding
a motor phase winding was open at power up
Bad Encoder
(not implemented at this time)
Warnings
CCW Limit
when the DL (Define Limits) command is configured, Input#2 has been
triggered
CW Limit
when the DL (Define Limits) command is configured, Input#1 has been
triggered
Under Voltage
the DC bus voltage has dropped below 10 VDC
Move While Disabled
a move was commanded while the drive was disabled
Current Foldback
the command current exceeded either the boost or continuous limit
Blank Q Segment
does not apply to an S model
Flash memory
a flash memory error occured when saving parameters
NV Memory Error
the flash memory was found corrupted at power-up
Comm Error
the drive has detected a communications error either in the hardware
or in the protocol