23
Rev. 1.0
0006302011
SSM24C User Manual
+86-400-820-9661
Options for
IN2
are:
•
At end of travel, CCW limit input will be closed
•
At end of travel, CCW limit input will be open
•
Not used - generic programmable input
Options for
IN3
are:
•
Not used - generic programmable input
•
Enable motor when closed - the motor has no power when the input is open
•
Enable motor when open - the motor has no power when the input is closed
•
Reset alarm when closing - an alarm or fault can be cleared by closing the input
•
Reset alarm when opening - an alarm or fault can be cleared by opening the input
Options for
Output(OUT)
are:
•
Not used - generic programmable output
•
Closed on fault - the output will close if a fault occurs
•
Open on fault - the output will open if a fault occurs
•
Closed to release brake - the output controls a fail safe brake relay
•
Open to release brake - the output opens to release the brake
•
Tach out - the output produces pulses relative to the motor position
•
Closed when position error less than - enter a count value in the box
•
Open when position error less than - enter a count value in the box