3.2 Digital Outputs
3.2.1 Y1, Y2, Y3 Digital Outputs
•
Y1 can be used as alarm output or general purpose output.
•
Y2 can be used as brake output or general purpose output.
•
Y3 cab be used as motion output , tach output, timing signal output(50pulse/rev) or general
purpose output.
Please use STB Configurator software for Y1,Y2 and Y3 function configuration.
Following graphs shows some common connection methods for the outputs:
NOTE: Do not connect the outputs to more than 30VDC power supply. And the current of
each output terminal must not exceed 100mA.
Connecting a sinking output
Connecting a sinking output with PLC’s input
Connecting a sourcing output with PLC’s input
Driving a relay
MSSTB
Drive
5-24 VDC
Power Supply
+
–
Load