8
General
10"
254
Max
17"
432
Min
8 12 "
216
Min.
Mantel
Side Wall
Hearth Protection
Not Required
Faceplate
17"
432
Minimum
10"
254
Max
Allowable
Mantel
Area
25"
27"
29"
31"
33"
35"
37"
39"
10"14"18"24"26"30"34"38"
21"
19"
17"
23"
24"
610mm
34"
864mm
15"
381mm
Gas and Electrical
Supply at Right Side
6"
152mm
24"
610mm
Section 2: Installation Dimentions
Install Dimensions
Clearances
Figure 2.0
Install dimensions
Figure 2.1
Install clearances
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
30FID
20"
14"
30"
5"
20"
16"
10"
8½"
34FID
24"
15"
34"
6"
24"
23"
10"
8½"
The install size requirements of your fireplace insert are dependent on
several factors. Gas line location, electrical connection and gas line type
can play into what the minimum installation size can be. The diagram
below illustrates the smallest possible size requirement of this model.
Please take into consideration these other factors when determining
if this appliance will fit into your masonry or manufactured fireplace.
The Insert is designed and built to be installed into masonry or
manufactured fireplaces. There is no requirement to have a non-
combustible hearth in front of the unit. Clearances to the underside of
the mantel or sidewall are measured from the edge of the door/screen
front. The Mantel is shown as 10” maximum at minimum distance from
the door edge top. The mantel can be extended further providing that
you increase the height proportionately. For instance, if you want a
mantel that is 2” beyond the maximum, you have to install it 2” above
the minimum.
**Hearth protection is not required if the unit is installed with a 2"
(50.8mm) elevation or greater above the hearth surface. See the section
on 4 sided surround options.
Faceplate
Mantel
Hearth
protection not
required**
Gas and electrical
supply at right side
Side wall