XG0523 - 170223
41
Operation
9. Disconnect the Fan Wire
Harness at the back as well.
11. Remove the Blowers from
the Fireplace.
13. At this point, if you want to test the Blower operation, do so with
the Gas Supply turned off or disconnected. To test the Blower
operation, you will need to re-connect the electrical supply
temporarily. Disconnect the Electrical Supply after testing the
Blowers.
14. Re-install the Outer Shell Rear panel.
15. You will need to replace the Flue Collar Plate Gasket prior to re-
installation into the cavity.
16. Replace the Flue Connector Plate Gasket.
17. Re-install the unit into the Cavity. See the section on Vent
Connections.
18. Re-install the Face Plate Panels. See the section on Setup.
19. Re-connect the Electrical Supply.
10. Remove 3 screws that
mount each fan in place.
12. Install both new Blowers.
Secure the Wire Harness
with the Zip Straps.
Figure 10.12
Figure 10.6
Figure 10.8
Figure 10.10
Figure 10.7
Figure 10.9
Figure 10.11