XG0523 - 170223
34
Operation
Initializing the System for the first time
1. Set master override switch to off position.
2. Install four (4) AA batteries into the battery holder.
3. Install three (3) AAA batteries in the back of the remote
control. Note the polarity of batteries and install them as
indicated by the silk screen (+/-) on the holder.
4. Connect AC Power (115 volts, 60 Hz) to fireplace.
Operating the System for the first time
Press SW1 button on the control module. The control module will
beep three (3) times and an amber LED is illuminated to indicate
that the IFC (control board) is ready to synchronize with a remote
control within 10 sec. Push the ON button. The control module
will "beep" four (4) times to indicate transmitter's command is
accepted.
The System is now initialized.
Temperature Indication Display
With the system in the "Off" position, press the Thermostat Key
and the Mode Key at the same time. Look at the LCD screen on
the Remote Control to verify that a C or F is visible to the right of
the Room Temperature display.
Continuous Pilot (CPI) Selection
(Optional)
In cold weather climates, the pilot burner can stay on
continuously to prevent condensation or cold air temperatures
near the fireplace glass. Note, some jurisdictions do no permit
use of continuous pilot system. Check local codes or contact your
Montigo dealer.
With the system in "off" position press the Mode Key, see Figure
8 Sec.10, to index to the CPI mode icon, see Figure 22 Sec.10.
Pressing the Up Arrow Key will activate the Continuous Pilot
Ignition mode (CPI). Pressing the Down Arrow Key will return to
IPI. A single "beep" will confirm the reception of the command.
NOTE:
- Requires CPI/IPI jumper cable installed
Turn On the Fireplace
With the system Off, turn the master override switch to on and
press the On/Off Key on the Remote Control. The Remote Control
display will show some other active Icons on the screen. At the
same time the Control Module will activate the fireplace. A single
"beep" from the Control Module will confirm reception of the
command.
Turn Off the
Fireplace
With the system On, press
the On/Off Key on the
Remote Control. The Remote
Control LCD display will only
show the room temperature.
At the same time the Control
Module will turn off the
fireplace. A single "beep"
from the Receiver confirms
reception of the command.
Figure 9.12
Remote Control display in Fahrenheit & Celsius
Figure 9.12a
Continuous Pilot / Intermittent Pilot Selection
Figure 9.13
Remote Control Display