OPTIONS
Continued on next page
NG45009,00000BD -19-19JUN19-1/2
Liquid Fertilizer
3 point Mounted Planters
Pump Mounting and Hose Arrangement
The squeeze pump is shipped with the discharge
manifold in the rearward or non-operating position. Before
operating or mounting the pump, position the discharge
manifold in the forward or operating position and secure
by tightening the wing nuts.
The pump should always be mounted even with or
lower than the fertilizer tank for accurate metering. The
rate of liquid fertilizer application is determined by the
combination of sprockets on the squeeze pump and the
drive shafts (see chart). When changing the sprocket
combinations, check that the sprockets are in alignment,
that the sprocket retaining collars are tight and that the
chain tension is restored.
The shut-off valves should be closed to shut off the flow
when the pump is not in use, either overnight, or for an
extended amount of time. Also close the valves when
servicing either the pump or the hoses.
To prolong the life of the hoses, the discharge manifold
must be repositioned to the rearward position when not is
use to prevent hose distortion.
The discharge pump must be in the forward position when
the pump is in operation. To reposition the manifold,
loosen the wing nuts and slide the manifold forward and
sideways or rearward as required and retighten the nuts.
CAUTION: Agricultural chemicals can be
dangerous. Improper use can result in injury to
persons, animals, and soil. Handle with care and
follow instructions of the chemical manufacturer.
IMPORTANT: If the fertilizer is placed too close
to the seed, it may cause germination or
seedling damage especially if used in amounts
in excess of the fertilizer manufacturer’s
recommendations. Consult with a fertilizer
dealer or manufacturer for the correct amount
and placement of fertilizer.
Delivery Rate Chart
The following delivery rate chart provides an approximate
application rate only. Actual delivery will vary with
temperature and the type of fertilizer being used.
Chart is shown in gallons per acre. This chart is for a
pump with a ½" hose. For settings with a 5/16" hose, cut
gal/acre in half.
APY09749
—UN—13MAR19
Discharge Manifold Rearward
APY09750
—UN—13MAR19
Discharge Manifold Forward
16 Tooth Driver Sprocket
Sprocket
Part #
Driven
40”
38”
36”
30”
L-1383
8
21.9
23.1
23.9
29
L-1384
9
19.1
20.4
21
25.3
L-1385
10
17.2
18.3
18.9
22.7
L-1386
15
11.4
12.1
12.5
15
L-1381
20
8.6
9.1
9.4
11.3
L-1387
22
7.7
8.2
8.5
10.2
L-1388
23
7.5
8
8.3
9.6
L-1389
26
6.7
7.1
7.3
8.8
L-1390
30
5.8
6.2
6.4
7.7
L-1391
31
5.6
5.9
6.1
7.4
L-1392
32
5.5
5.8
6
7.3
Gallons per Acre
60-19
061919
Содержание 7x7 NG Plus 4 Series
Страница 1: ......
Страница 38: ...FRAME 7 x 7 Stacker Bar 20 15 061919 PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...VACUUM 40 6 061919 PAGE INTENTIONALLY LEFT BLANK ...
Страница 89: ...OPTIONS 60 28 082719 PAGE INTENTIONALLY LEFT BLANK ...
Страница 90: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...PAGE INTENTIONALLY LEFT BLANK ...
Страница 94: ......