OPTIONS
NG45009,00000BE -19-28MAY19-3/3
To test your desired fertilizer to determine lbs/acre use
the chart below.
First measure out a distance of 328 feet in a row.
1. Remove one hose from a fertilizer hopper and attach
a plastic bag, or other container, under the opening in
the hopper.
2. Engage the fertilizer attachment and drive forward the
pre-measured distance of 328 feet (100 meters).
3. Weigh the amount of fertilizer caught in the container
(in ounces).
4. Find your row spacing on the below chart, locate the
approximate ounces and follow the chart up to see
CALIBRATION CHART
NOTE: Because all fertilizers do not have the same
density and the granules can be irregular, it is
impossible to furnish an exact setting chart.
lbs/ acre
Row
Spacing
80
90
100
120
130
140
170
190
200
210
220
22”
14
16
18
22
23
25
31
34
36
38
40
30"
20
22
24
29
32
34
42
47
49
51
54
36"
24
26
29
35
38
41
50
56
59
62
65
40"
32
36
40
48
52
56
68
76
80
84
88
60-25
061919