19
EDID Commands (continued)
(note that the DIP switches must be set to 1111 for these to work)
Command
Function
Feedback Examples
EDIDG[x].
Get EDID data from output [x]
and display the output port
number
Hexadecimal EDID data and
carriage return character
EDIDMInit.
Restore the factory default EDID
data for each input
EDIDMInit.
EDIDM[X]B[Y].
Manual EDID switching. Enable
input [Y] to learn the EDID data
of output [X]. If the EDID data is
not available, then set it as
initialized EDID data.
EDIDM3B1
EDID/[x][y].
Set the EDID data of input port
[x] to built-in EDID # [y].
[y]=0~11 corresponding to the 12
embedded EDID settings. Refer
to the
EDID MANAGEMENT
section above.
EDID/[x]/[y]
EDIDUpgrade[x].
Upgrade EDID data through the
RS232 connection. [x]=input
port 1~4, 5=All input ports.
When the switch receives the
command, it will show a
message to prompt you to send
the EDID file (.bin file). The
operation will be canceled after
10 seconds.
Please send the EDID file
EDID Upgrade OK!