![Monogram Monogram ZIFS36N RH Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/monogram/monogram-zifs36n-rh/monogram-zifs36n-rh_technical-service-manual_1827780012.webp)
– 10 –
Operating Characteristics
Note: Refer to Component and Connector
Locator Views.
• Refer to Schematics and Strip Circuits.
Component Description
The compressor, dryer, and condenser are
located in the machine compartment on the top of
the cabinet. The evaporator is located on the
inside of the cabinet at the bottom of the back wall.
The capillary is soldered to the compressor
suction line. This arrangement serves as a heat
exchanger. The temperature control is located in
the top of the inside of the cabinet. The evaporator
fan is also located in the top of the inside of the
cabinet, behind the temperature control.
Electrical Operation (Freezer)
115V is provided from the power source to the
temperature control. The temperature control is a
thermostatic switch that closes when cabinet
temperature is higher than the control setting.
When closed, the temperature control provides
115V to the defrost control. The defrost control
contains a motor/cam mechanism that switches
the defrost control between defrost mode and
cooling mode. When in cooling mode, the defrost
control provides 115V to the compressor and to
the condenser fan. The condenser fan and
compressor always operate at the same time. In
addition to the compressor and condenser fan, the
defrost control provides 115V (in cooling mode)
through the cabinet door switch (evaporator fan
circuit) to the evaporator fan delay switch. The
door switch opens the evaporator fan switch
circuit when the cabinet door is open. The
evaporator fan delay switch opens when the
evaporator temperature has raised to 45°F and
closes when the evaporator temperature has
lowered to 25°F. When closed, the cabinet door
switch and evaporator fan delay switch provide
115V to the evaporator fan.
Electrical Operation (Refrigerator)
115V is provided from the power source to the
temperature control. The temperature control is a
thermostatic switch that closes when cabinet
temperature is higher than the control setting.
When closed, the temperature control provides
115V to the drain pan fan and defrost thermostat
switch. When closed, the defrost thermostat
switch provides 115V to the compressor and to
the condenser fan. The condenser fan and
compressor always operate at the same time.
115V is also provided from the power source to
the evaporator fan. The door switch opens the
evaporator fan switch circuit when the cabinet
door is open.
Air Movement
The cabinet is designed so that when the
evaporator fan is operating, air is drawn through
the evaporator and then up the back of the cabinet
through two ducts. At the top of the cabinet, the air
is drawn out of the ducts and through the
evaporator fan into the upper rear duct. Air moves
out of the upper rear duct and into the main part of
the cabinet. In the main part of the cabinet, the
cold air falls into the lower part of the cabinet and
is drawn into the evaporator again.
Содержание Monogram ZIFS36N RH
Страница 7: ... 5 Specifications ...
Страница 8: ... 6 ...
Страница 11: ... 9 Notes ...
Страница 13: ... 11 GEA00637 Refrigerator Air Flow GEA00860 Freezer Air Flow ...
Страница 14: ... 12 Notes ...
Страница 30: ... 28 Notes ...
Страница 44: ... 42 Exploded parts view and list for Model No ZIFS36NDALH Refer to microfiche for other model information ...
Страница 46: ... 44 Exploded parts view and list for Model No ZIFS36NDALH Refer to microfiche for other model information ...
Страница 48: ... 46 Exploded parts view and list for Model No ZIFS36NDALH Refer to microfiche for other model information ...
Страница 50: ... 48 Exploded parts view and list for Model No ZIFS36NDALH Refer to microfiche for other model information ...
Страница 52: ... 50 Exploded parts view and list for Model No ZIFS36NDALH Refer to microfiche for other model information ...
Страница 54: ... 52 Exploded parts view and list for Model No ZIRS36NDARH Refer to microfiche for other model information ...
Страница 56: ... 54 Exploded parts view and list for Model No ZIRS36NDARH Refer to microfiche for other model information ...
Страница 58: ... 56 Exploded parts view and list for Model No ZIRS36NDARH Refer to microfiche for other model information ...
Страница 60: ... 58 Exploded parts view and list for Model No ZIRS36NDARH Refer to microfiche for other model information ...
Страница 62: ... 60 Notes ...