C120S Technical Manual TSP093.doc Issue 1.2 – January 2005
Money Controls 2005. All rights reserved.
Page 11 of 15
5. Environmental
Specification
Table 5: Environmental Ranges
Standard Operating Temperature and
Humidity range:
0
°
C to 60
°
C
0% to 75% RH non-condensing
Extended Operating Temperature and
Humidity range:
**
-25
°
C to 60
°
C
0% to 95% RH non-condensing
Storage temperature range:
-40
°
C to 70
°
C
0% to 95% RH non-condensing
Rate Of Change
< 40% per hour
(Recovery time by the acceptor after a temperature step change is 1 hour per 20
°
C.
Maximum operating rate of change 20
°
C per hour.)
**
Accept rates may fall outside Standard Operating Temperature and Humidity ranges
5.1. Fluid
Ingress
The design of the product is such that the passage of liquids entered through the coin entry
port are routed via the reject path and away from sensitive hardware circuits.
The PCB is conformally coated to withstand the presence of moisture and limited fluid
abuse.
5.2. EMC
Product complies with European generic standards EN50081-1 and EN50082-1.
5.3. Safety
Product meets the safety requirements of EN41003 and EN60950
5.4. Shock, Bump, Vibration & Impact
This product complies with:
Packaged vibration:-
BS2011: part 2.1 Fdb
Packaged shock:-
ISTA - Procedure 1A, Vibration test method A
Packaged drop:-
ISTA - Drop test procedure 1A
Packaged compression:-
ISTA - Static compression test, Method B
Installed vibration:-
IEC 68-2-6, Fc
Installed shock:-
IEC 68-2-27, Ea
5.5. Time
– No limited life components fitted