4. Mechanical 

Specification

4.1. External 

Dimensions / Mechanical Interfaces

The space envelope, coin entry and exit positions, together with the mounting details are
detailed in 

Figure 2

.

4.2. Orientation:-

The C120S may be orientated at ±3

o

 in any plane from nominal without affecting coin accept

rates.

4.3. Acceptance 

Rates

The C120S is capable of accepting coins at a rate of two coins per second on “normal” round
coins. Coins entered at faster rates may be rejected due to 2

nd

 close coin errors, which may

jeopardise the 88% coin acceptance rate. Coin acceptance is inhibited following a successful
validation until the Host controller has acknowledged the previous acceptance message, or a
timeout condition has occurred. The timeout is nominally 50ms. A timer will be available to
slow the accept rate further if the system [payphone] demands it. Coins inserted quickly
should be able to be cleared quickly, without a coin jam arising.

In addition to the standard security windows, other window types may be generated which
provide higher security over both standard and extended temperature ranges.

The actual acceptance rates shall be determined on development of each coin set and shall
be defined in the individual coin set specification. The C120S accepts up to 16 different coin
types and the parameters for these are stored within the mech. in a non-volatile memory. It is
possible to download new or amended data from the Host controller or alternative
programming equipment, via the serial link.

4.4. Accept 

gate

The coin accept gate is operated by a low powered solenoid to minimise energy use. The
default coin path with the solenoid de-energised is to reject the coin.

Содержание C120S

Страница 1: ...ithin this document Money Controls Ltd shall not incur any penalties arising out of the adherence to interpretation of or reliance on this standard Money Controls Ltd will provide full support for thi...

Страница 2: ...MC 11 5 3 Safety 11 5 4 Shock Bump Vibration Impact 11 5 5 Time 11 6 Software Specification 12 6 1 ccTalk spec additional commands 12 6 2 ccTalk structure and commands 12 6 3 Initialisation 12 6 4 Mes...

Страница 3: ...l TSP093 doc Issue 1 2 January 2005 Money Controls 2005 All rights reserved Page 3 of 15 1 Diary Of Changes Issue 1 0 February 2004 1st Issue Issue 1 1 June 2004 Changed footer Issue 1 2 27th January...

Страница 4: ...onditions specified in Section 5 2 2 General A coin reject mechanism is provided which will open the C120S to allow coin jams or foreign debris to be cleared and fall into the reject chute The C120S o...

Страница 5: ...s when supply is out of spec Table 2 Current Consumption Note Idle current is that state where the power is applied but prior to a coin being detected at the wakeup sensor This is typically the condit...

Страница 6: ...ial data line 2 RxD1 Receive flash data 5V TTL CMOS 3 Ready Active low 4 TxD1 Transmit flash data 5V TTL CMOS 5 Reset Active low when supply is outside spec 6 CNVSS Active low for flash program mode 7...

Страница 7: ...c Levels The logic levels between the C120S and the payphone controller is standard CMOS level that is Logic 0 shall be less than 30 of 5V supply and Logic 1 shall be greater than 70 of 5V supply The...

Страница 8: ...e or a timeout condition has occurred The timeout is nominally 50ms A timer will be available to slow the accept rate further if the system payphone demands it Coins inserted quickly should be able to...

Страница 9: ...d to produce coins world wide Coins may have holes or be non circular providing that they are capable of rolling uniformly down a ramp at an angle of 15 to the horizontal Tokens may have identificatio...

Страница 10: ...C120S Technical Manual TSP093 doc Issue 1 2 January 2004 Money Controls 2005 All rights reserved Page 10 of 15 Figure 2 C120S External Dimensions...

Страница 11: ...ture and Humidity ranges 5 1 Fluid Ingress The design of the product is such that the passage of liquids entered through the coin entry port are routed via the reject path and away from sensitive hard...

Страница 12: ...ket upload program Sub header 245 Delete all coin windows All the other C120P commands SEE TSP068 for details are supported apart from header 200 Upload coin data 6 3 Initialisation Whenever the Host...

Страница 13: ...follows Coin detected in coin acceptor Coin acceptor changes from IDLE to RUN state Coin validated and result calculated true reject error READY signal activated by coin acceptor Host Controller reque...

Страница 14: ...t and Diagnostics A self test can be invoked by command from the Host controller 8 3 Reliability Life expectancy service life of 10 years or 1 million coins whichever is the sooner 8 4 MCBF Reliabilit...

Страница 15: ...ed only to assist the reader in the use of this product and therefore Money Controls shall not be liable for any loss or damage whatsoever arising form the use of any information or particulars in or...

Отзывы: