NICE5000 User Manual 7 Description of Function Codes
- 153 -
Bit
Function
Description
Default
Bit8
Time-based service
floor function
It is used to enable the function of responding to
different floor calls during different time periods.
For details, see the description of F6-35 to F6-52.
0
Bit9
Disabling reverse
floor number clear
The system clears all the current car calls every time
the elevator changes the direction by default. When this
function is enabled, the function of clearing reverse floor
numbers is disabled.
0
Bit10
Buzzer not tweet
upon re-leveling
The buzzer inside the car does not tweet upon re-
leveling.
0
Bit11
Car call deletion
A car call can be deleted by pressing the corresponding
button twice consecutively (at an interval of 0.5s). If the
call is being executed, it cannot be deleted.
1
Bit12
Hall call deletion
A hall call can be deleted by pressing the hall call button
twice consecutively (at an interval of 0.5s).
0
Bit13
Timed elevator lock
It is used to enable the timed elevator lock service.
The elevator lock time is set in F6-22.
0
Bit14
Arrival gong disabled
at night
The arrival gong is disabled from 22:00 p.m. to 7:00
a.m.
0
Bit15
Reserved
-
0
F6-10 Elevator function selection 2
Bit0
Door open/close
holding at open limit
The system still outputs the door open/close command
upon door open/close limit.
0
Bit1
Cancelling door
open/close
command at a delay
after door open/
close limit
The door open/close command is cancelled at a delay
after door open/close limit.
The delay time is set in F8-22.
1
Bit2
Cancelling door
open/close
command cancelled
immediately at door
open/close limit
The system immediately cancels the door open/close
command after receiving the door open/close limit.
0
Bit3
Not judging door
lock state at door
close output
On normal conditions, the system determines that the
door is completely closed only when the door close limit
signal is active and the door lock is applied.
If this function is enabled, the system need not judge
the door lock state.
0
Bit4
Auto reset for RUN
and brake contactor
stuck
If the feedback of the RUN and brake contactors is
abnormal, faults Err36 and Err37 are reported, and you
need to manually reset the system.
With this function, the system resets automatically after
the fault symptom disappears. A maximum of three auto
reset times are supported.
1
Содержание NICE 5000
Страница 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions...
Страница 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Страница 24: ...2 Product Information...
Страница 34: ...3 Mechanical and Electrical Installation...
Страница 71: ...4 Use of the Commissioning Tools...
Страница 79: ...5 System Commissioning and Functions...
Страница 99: ...6 Function Code Table...
Страница 130: ...6 Function Code Table NICE5000 User Manual 128...
Страница 131: ...7 Description of Function Codes...
Страница 201: ...8 Troubleshooting...
Страница 220: ...8 Troubleshooting NICE5000 User Manual 218...
Страница 221: ...9 EMC...
Страница 230: ...9 EMC NICE5000 User Manual 228...
Страница 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...