NICE5000 User Manual 7 Description of Function Codes
- 133 -
asynchronous motor but keep the same for the PMSM.
Ensure that these motor parameters are set correctly. Incorrect setting affects the motor
auto-tuning and the vector control effect.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-06
Stator resistance
0.000–65.000
0.000
Ω
★
F1-07
Rotor resistance
0.000–65.000
0.000
Ω
★
F1-08
Leakage inductance
0.00–650.00
2.34
mH
★
F1-09
Mutual inductance
0.1–3000.0
66.6
mH
★
F1-10
Magnetizing current
0.01–650.00
10.7
A
★
These parameters are obtained by means of motor auto-tuning. After the motor auto-tuning
is completed successfully, the values of these parameters are updated automatically.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-11
Auto-tuning mode
0: No operation
1: With-load auto-tuning
2: No-load auto-tuning
3: Current loop parameter
identification (only for
synchronous motor)
0
-
★
It is used to select the auto-tuning mode.
• 1: With-load auto-tuning
It is static auto-tuning for the asynchronous motor and rotary auto-tuning for the
synchronous motor.
• 2: No-load auto-tuning
It is complete auto-tuning, by which all motor parameters can be obtained.
• 3: Parameter identification
When F1-11 is set to 2 (No-load auto-tuning), the motor must be completely
disconnected from the load; otherwise, the auto-tuning effect will be affected.
When "TUNE" is displayed on the operation panel, you need to manually release
the brake before starting auto-tuning. For details on the auto-tuning process, see the
description in section 5.4.
Function Code
Parameter Name
Setting Range
Default Min. Unit Property
F1-12
Angle-free auto-tuning
function selection
Bit1: Angle-auto-
tuning-free
0
-
★
When Bit1 =1, motor auto-tuning is not required, because the inspection running process at
first-time power-on includes the motor auto-tuning process.
Ensure that motor phase sequence and encoder wiring are correct.
Содержание NICE 5000
Страница 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions...
Страница 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Страница 24: ...2 Product Information...
Страница 34: ...3 Mechanical and Electrical Installation...
Страница 71: ...4 Use of the Commissioning Tools...
Страница 79: ...5 System Commissioning and Functions...
Страница 99: ...6 Function Code Table...
Страница 130: ...6 Function Code Table NICE5000 User Manual 128...
Страница 131: ...7 Description of Function Codes...
Страница 201: ...8 Troubleshooting...
Страница 220: ...8 Troubleshooting NICE5000 User Manual 218...
Страница 221: ...9 EMC...
Страница 230: ...9 EMC NICE5000 User Manual 228...
Страница 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...