7 Description of Function Codes NICE5000 User Manual
- 178 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-11
Forced door close time
5–99
15
s
☆
If the forced door close function is enabled, when there is no door close signal after the time
set in this parameter is reached, the system enters the forced door close state and sends a
forced door close signal.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-12
Door close protection time
5–99
15
s
☆
It is used to set the door close protection time.
After outputting the door close command, if the system does not receive the door close limit
signal after the time set in this parameter, the system re-closes the door. When the door
open/close times reach the value set in Fb-13, the system reports fault Err49.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-13
Door re-open times
0–20
0
-
☆
It is used to set the door re-open/re-close times allowed when door open/close is abnormal.
Note
If this parameter is set to 0, it indicates that door re-open is not supported; in this case, the
elevator keeps opening/closing the door if it does not receive the door open/close limit signal.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fb-14
Door state of standby elevator
0–2
0
-
☆
It is used to set the door state when the elevator is in stop and standby state.
The values are as follows:
• 0: Closing the door as normal at base floor
• 1: Waiting with door open at base floor
• 2: Waiting with door open at each floor
Function Code
Parameter Name
Setting Range Default
Unit Property
Fb-15
Door open holding time for hall call
1–30
5
s
☆
It is used to set the door open holding time when there is a hall call. The elevator closes the
door immediately after receiving a door close command.
Function Code
Parameter Name
Setting Range Default
Unit
Property
Fb-16
Door open holding time for car call
1–30
3
s
☆
Содержание NICE 5000
Страница 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions...
Страница 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Страница 24: ...2 Product Information...
Страница 34: ...3 Mechanical and Electrical Installation...
Страница 71: ...4 Use of the Commissioning Tools...
Страница 79: ...5 System Commissioning and Functions...
Страница 99: ...6 Function Code Table...
Страница 130: ...6 Function Code Table NICE5000 User Manual 128...
Страница 131: ...7 Description of Function Codes...
Страница 201: ...8 Troubleshooting...
Страница 220: ...8 Troubleshooting NICE5000 User Manual 218...
Страница 221: ...9 EMC...
Страница 230: ...9 EMC NICE5000 User Manual 228...
Страница 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...