The pressure accumulator tank is mounted in the water bay near
the water pump. The accumulator tank will need to have mainte-
nance checks completed bi-monthly. The accumulator features:
1.
Smooth flow from the faucets.
2.
Reduced water pump cycling.
3.
A precharged air cushion.
4.
Elimination of pulsations and water hammer.
5.
Pressure of water at faucets.
The accumulator tank has a tire valve for checking the air pres-
sure in the tank. The precharged pressure must not exceed the
water pump cut-in pressure, the pressure at which the pump
restarts. The water pump has a cut-in pressure at 25 psi. Air pres-
sure in the accumulator tank should be set at 18 to 22 psi and
should not exceed 25 psi. To check the air pressure in the accumu-
lator tank the water pump and city water will need to be off so that
the water pressure is relieved. Open a faucet to relieve the remain-
ing water pressure. Using a tire air pressure gauge, one which reads low air
pressure, check the accumulator tank pressure bi-monthly. In the event you
need to add air pressure to the accumulator tank, a manual pump is recom-
mended. Airflow and pressure from a compressed air system can overcharge
the tank too quickly causing the tank to rupture.
A 2-stage filtration system if used and consists of the following filters:
•
First Stage 5 Micron Sediment Filter:
For reduc-
tion of suspended solids, dirt and rust down to 5
microns in size. Life expectancy varies with incom-
ing water condition. Recommended change of six
months to one year depending on incoming water
quality and use.
•
Second Stage 56 Cubic Inch Granular Activated
Carbon Filter:
Improves water quality by reducing
volatile organic chemicals, chlorine, tastes and
odors. Capacity of 1,500 gallons. Recommended
change of six months to one year depending on
incoming water quality and use.
Water Systems
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S I G N A T U R E
6 • 1 6 4
PRESSURE
ACCUMULATOR
TANK
WATER FILTERS
Remove tank valve cap to check air pressure.
Primary mesh
type cartridge.
In
flow
Out
flow
Secondary
plastic type
cartridge.
Содержание SIGNATURE 2001 series
Страница 1: ......
Страница 3: ...FOLD CUT ALONG DOTTED LINE FOLD...
Страница 7: ......
Страница 25: ......
Страница 73: ...Driving Safety SIGNATURE SERIES 2 7 3 NOTES...
Страница 75: ......
Страница 99: ...Care Maintenance SIGNATURE 3 9 9 NOTES...
Страница 101: ......
Страница 127: ......
Страница 157: ......
Страница 177: ......
Страница 187: ......
Страница 223: ......
Страница 259: ......
Страница 317: ...Chassis Information SIGNATURE 1 0 3 1 7 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Страница 318: ...Chassis Information SIGNATURE 1 0 3 1 8 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Страница 319: ...Chassis Information SIGNATURE 1 0 3 1 9 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Страница 320: ...Chassis Information SIGNATURE 1 0 3 2 0 Date Mileage Dealer Address Service Remarks CHASSIS LOG...