4
2.3
Warnings
Owner should ensure by adequate supervision that correct safety, installation, maintenance and
operating procedures described in this manual, as well as recognized industry practice, are followed
by all personnel.
All panels must be in place during normal operation.
The top of the machinery should not be used for storage.
Power sources or energy types referred to in this manual are water and electricity.
This machinery is not for use in hazardous or explosion proof environments.
Under normal operating conditions, the decibel level of the machinery is 67 db or lower.
Any alteration, additions or modifications to any part of the system must receive prior written
approval from Mokon’s Engineering or Customer Service Departments.
Refer to serial tag for motor and heater electrical information and schematic drawing number.
2.4
Electrical Connections
Warning: The Mokon temperature control system, as with all high voltage
electrical equipment, should be connected according to all applicable state
and local codes. All installation, maintenance, service, repair, adjustment,
and operation should be done only by qualified trained electrical
personnel who have read and completely understood this instruction
manual.
Before operating the Mokon temperature control system, the grounding
wire must be connected. The grounding wire is the green or green and
yellow wire connected to the frame of the system.
Connect ground wire to the ground screw (labeled PE or GND) located in the electrical box. Connect
power lines L1, L2, L3, to disconnect switch or terminal blocks marked L1, L2, and L3 respectively,
inside the electrical box. Overcurrent protection of the supply conductors should be sized according
to The National Electrical Code (NEC) and any other applicable state and local codes.