Section 2 – Installation
2.1
Unpacking
Upon arrival inspection should be done to assure there was no damage during shipping. In
addition, all electrical and mechanical connections should be inspected to ensure that they are
secure and tight. This includes all electrical terminations, mechanical fitting union bulbs,
compression fittings, etc.
Note: Refer to Section 4.1 Maintenance and service.
The maximum weights of the Mokon water systems when drained of water are:
Duratherm - 475 lbs (160 kg)
Dual Zone Duratherm - 950 lbs (232 kg)
Hydrotherm II - 175 lbs (80 kg)
Minitherm - 110 lbs (50 kg)
Properly rated equipment should be used to move this machinery.
When removing system from pallet, lift from bottom only. Care should be taken to ensure that the
system will not tip. After removing from pallet, the system should only be placed on a level
surface.
2.2
Location
Mokon systems should be located in an area that provides adequate space for pedestrian and
vehicle traffic. If this is not feasible, owner should provide additional safeguards including safety
signs.
For optimum system performance, allow adequate space and ventilation around entire system, as
well as a means to direct vapors away from work area.
There should be a minimum of four (4) feet of clearance around the entire Mokon system (all
sides) for adequate ventilation and operation of the system.
If braking casters are included, they must be in the locked position when system is in the operating
position. Prior to moving, unlock the casters.
Customer supplied and installed air vents (mechanical or electrical) should be placed at the highest
point in the process for application where the process height is greater than eight (8) feet above
Mokon system.