Switching on Contactors DIL-
SWD-32-001, DIL-SWD-32-002
40
The terminals on the SmartWire-Darwin module for DILM are
suitable for cables AWG24 to AWG16 and flexible cables
with a cross-section of 0.25 mm
2
to 1.5 mm
2
.
When using core end sleeves it has to be ensured that the
sleeve length is at least 8 mm.
The following jumpers can be used for wiring reversing
starters.
Table 4:
Jumpers for reversing starters
In combination with the jumpers DILM12-XEV the circuit fig.
13 should be used. On the other hand, an electrical interlock
with wire jumpers should be implemented according to the
circuit fig. 14.
A manual or electrical ON or OFF command for the contactor
can take place in addition with the aid of the 1-0-A switch in
the device version DIL-SWD-32-002.
The switch positions are as follows:
• 1 = Contactor ON
• 0 = Contactor OFF
• A - switching command via SmartWire-Darwin
h
Caution!
The wiring sets DILM12-XRL and PKZM0-XRM12 must not
be used for the assembly of the reversing starters.
The A2 connection of the contactors must not be bridged.
DILM7 - DILM15
DILM17 - DILM32
L1, L2 and L3 parallel
DILM12-XP2
DILM32-XRL
Phase switch L1 and L3, L2 parallel
DILM12-XR
DILM32-XRL
Electrical interlock
DILM12-XEV
-