3.1 Place of installation and placement
CAUTION
The installation and ordinary or extraordinary maintenance of the oven must be performed
exclusively by authorized technicians or, however, by qualified personnel in compliance with
the safety regulations and/or local provisions in force.
FOR THE EXECUTION OF THESE OPERATIONS IT IS INDISPENSABLE
TO BE IN POSSESSION OF ALL THE NECESSARY MEASUREMENT
TOOLS IN PERFECT WORKING EFFICIENCY AND PERIODICALLY CALIBRATED (see
Paragraph 1.3).
The producer declines all responsibility in case of failure to observe these obligations.
Guarantee a distance of at least 30 cm from the ceiling if it is made of combustible material or
if it is not thermally insulated.
3.2 Power and water supply connection
Connection to power grid
The connection to the power supply grid must be performed in accordance with the international,
national and local regulations in force.
Make sure, before connecting the oven that the voltage and frequency of the grid correspond to the
values indicated on the technical data tag of the oven (figure 3 ) placed on the backside of the oven.
It is reminded that a variation of the maximum voltage of ±10 % is admitted.
The oven must be permanently connected to the power grid with a cable no less than H05RN-F type
(heavy duty poly-chloroprene rubber) or higher with the section of the leading wires based on the
maximum charge absorbed (see paragraph 1.3).
Part 3:
Instruction for installation and maintenance