E5 Gas Type Conversion
THIS APPLIANCE IS CONFIGURED TO OPERATE ON NATURAL GAS (NG). If gas type
conversion is not required then skip to the next section.
Your gas fire has been supplied with the necessary parts for gas conversion. Follow the steps on the
following pages to change from NG to ULPG/Propane or vice versa.
WARNING: The regulator that is supplied with the fire MUST NOT BE REMOVED.
Removal of the regulator, or replacing it with one not intended for use with this Escea fire, will void the
limited appliance warranty.
Turn off power and gas first.
Step 1:
Remove the Infill first by removing the 4 screws circled below, then remove the burners by
sliding them in the direction of the arrows below, start with both sides before removing the center
burner.
Step 2:
Change the burner jets with the jets supplied in kit set (see table on next page).
Step 3:
Replace the pilot jet (see tables below).
Note: Ensure the pilot jet is joined up to the olive before
inserting the jet into the pilot assembly (as shown below).