C8 Running the Powerflue Electrical Cable
Note: The powerflue terminal is powered from the appliance and must be connected to the appliance with the
supplied electrical cable only.
Note: Ensure that the appliance power supply is disconnected before making the connection to the terminal
The supplied electrical cable is 7m long; flue extension kits also include a powerflue electrical cable
extension.
Run the electrical cable from the cavity where the appliance will be installed to the hole in the outside
wall. Ensure it is not draped over, or in contact with, the outer shell of the appliance or the flues.
The cable must be kept clear from any other possible heat sources, sharp edges, or moisture. Fix it
appropriately and allow enough cable to be able to pull both the appliance and the powerflue terminal
out from their installed positions.
If you do not connect the powerflue electrical cable to both the fireplace and the
powerflue, this will result in an error when the fireplace is turned on.
Test the fan before continuing with the rest of the installation.
END OF SECTION C
By the end of this section, you should have:
□
A weather-tight installed powerflue terminal with clearance as specified by AS/NZ5601
□
Reasonable access to the terminal for maintenance purposes
□
Flue attached to the powerflue terminal leading back to the appliance with the correct
flue clearances
□
The electrical cable from the powerflue terminal run back to the appliance cavity in an
electrically safe manner