Creating the Hole in the Outside Wall
When cutting the hole in the outside wall, be mindful of how the installation of
the horizontal powerflue wall terminal will be finished; the installation must be
weatherproof.
Ideal Hole/Cavity Size for Horizontal Powerflue
Without Side Brackets
With Side Brackets
X
298mm
360mm
Y
298mm
298mm
Z
175mm
Excluding allowance for flue which exits here
The horizontal powerflue wall terminal can be attached to the wall in two ways:
A) From the front of the terminal:
B) By attaching the optional wall terminal installation brackets to the sides of the cavity and attaching
the horizontal powerflue wall terminal to these, from the front:
Attach the Ø100mm and Ø75mm flexible aluminium flues to the spigots on the rear of the horizontal
powerflue wall terminal using the hose band clamps supplied. Plug the powerflue electrical cable into
the back of the horizontal powerflue wall terminal.
Ensure that the electrical cable is firmly secured to the wall terminal or building to prevent damage or
disconnection if pulled.