C2 Flue Configuration (If more than 8m flue length is required)
If your flue system is greater than 8m long (up to 40m long), then please contact the Escea Advisory
Team at [email protected] for further guidelines.
C3 Installing the Horizontal Powerflue Wall Terminal Option
The horizontal powerflue wall terminal must be installed in the correct
orientation (the small horizontal slot should be at the bottom). This
allows for the correct operation of the flue system and prevents the
ingress of water.
The horizontal powerflue wall terminal must be weather tight when
installation is complete to prevent damage to the dwelling. It must be
installed by a suitably qualified person.
Fit the horizontal powerflue wall terminal into the hole and fix in place, making sure the installation is
sealed appropriately to prevent the ingress of water from outside the wall cladding. Take notice of the
label on the termination which shows the correct orientation of the terminal.
Note: It is the responsibility of the installer to ensure the horizontal powerflue wall terminal is installed to all
relevant building codes to ensure weather tightness.