1.5.4 Starting the Camera Using the Factory IP Address
If the camera's IP address is not known, you can start the camera with its factory IP
address. Section 3.6,
Starting the Camera Using the Factory IP Address, describes
this procedure in more detail.
1.5.5 Resetting the Camera to Factory Defaults
All settings of the MOBOTIX camera can be reset permanently to the factory default
settings. This makes sense if you have, for example, obtained a camera without
any information or you would like to reset all settings after testing the camera. In
order to perform this procedure, you need to have access to the administration
area of the camera (
admins
group). Open
Admin Menu > Reset …
to reset the
camera to factory defaults.
Note:
All defined users will be deleted and the admin password will be reset
to the factory default
when you reset the camera using
Admin Menu > Reset …
Proceed according to section 3.6,
Starting the Camera Using the Factory IP Ad-
dress, if you would like to maintain existing users.
1.5.6 Activating Event Control for Security Applications
In its default configuration, the camera's
event control and video motion detec-
tion features
are
not enabled
. In order to activate event control as a whole, open
Setup Menu > General Event Settings
and activate the
Arming
switch. Click on
the
Arm & Record
softbutton of the user interface in the browser to enable the
standard event features. The camera now displays the video motion detection win-
dow in the live image (dotted frame in the center) and the camera automatically
stores images as soon as the video motion window detects movements.
1.5.7 Deactivating Text and Logo Options
As the camera arming is deactivated in its default configuration (see preceding
section), the MOBOTIX camera only displays the Text
WWW.MOBOTIX.COM
, the
time stamp and the MOBOTIX logo at the top of the image. Once the camera arm-
ing has been activated (see above), the text at the bottom of the live image (event,
action and messaging symbols) will also appear.
You can deactivate the status text at the bottom and the text at the top left corner of
the live image by setting
Text Display
in the
Setup Menu > Text & Display Set-
tings
dialog to
Off. Setting
Text Display
to
Date & Time will only display the time
stamp in the live image.
In order to hide the logo in the live image, open
Admin Menu > Logo Profiles
and
set
Logo Display
to
Disable.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
25
/108
D22M Camera Manual Part 1
You can reset specific
parts of the configuration
If the dotted frame is
visible in the live image of
the camera, the camera is
armed
Text and logos can be also
deactivated or customized
to your liking