Troubleshooting
Chapter Five: Maintenance and Troubleshooting
45
Troubleshooting
The following sections contain basic information for identifying and solving problems with your device.
MKS also offers standard maintenance and repair services, including recalibration at the MKS Regional
Calibration and Service Centers.
General
Symptom Root
Cause
Correction
During hard close, closed
conductance fails spec
(<10-5 atm*cc/sec He).
O-rings on seal ring damaged or
worn.
Replace o-rings on seal ring using
procedure described in this manual.
Insufficient air pressure.
Increase pneumatic air pressure. Refer to
Table 10, page 16.
Missing interlock on 25 pin DI/DO
connector, pins 22 to 24.
Connect pin 22 to 24, or verify external
interlock wiring.
Pressure differential across gate too
high (see
Adjust operating conditions to stay within
maximum differential pressure
specification of the valve.
No 24V power is present at the
valve terminals.
Verify 24V power is applied to the valve.
Failed solenoid valve.
MKS Repair to replace.
Valve does not open.
Defective valve.
Return to MKS repair facility.
Insufficient air pressure.
Increase pneumatic air pressure. Refer to
Table 10, page 16.
Missing interlock on 25 pin DI/DO
connector, pins 22 to 24.
Connect pin 22 to 24, or verify external
interlock wiring.
Pressure differential across gate too
high (see
Adjust operating conditions to stay within
maximum differential pressure
specification of the valve.
No 24V power is present at the
valve terminals.
Verify 24V power is applied to the valve.
Failed solenoid valve.
MKS Repair to replace.
Valve does not close.
Defective valve.
Return to MKS repair facility.
Battery not sufficiently charged.
Valve should remain powered for 2 hours
to ensure fully charged batteries.
Valve does not close
when power is removed.
Battery needs to be replaced.
Order replacement battery and follow
procedure for replacing (see
Valve fails to control
pressure. Pressure
reported by valve is FS.
Sensor disconnected.
Reconnect sensor.
Valve fails to control
pressure. Pressure
reported by valve is low
or zero.
Manometer not powered.
Verify power to manometer.
Содержание T3PIA
Страница 3: ...MKS Type T3PIA Pendulum Valve With Analog TTL Interface...
Страница 8: ...viii This page intentionally left blank...
Страница 27: ...Electrical Information Chapter Two Installation 19 Figure 4 Top Panel of the T3P Unit...
Страница 32: ...Chapter Two Installation Startup 24 This page intentionally left blank...
Страница 60: ...Appendix C Dimensions 52...
Страница 61: ...Appendix C Dimensions 53...
Страница 62: ...Appendix C Dimensions 54...
Страница 63: ...Appendix C Dimensions 55...
Страница 64: ...Appendix C Dimensions 56...
Страница 65: ...Appendix C Dimensions 57...
Страница 66: ...Appendix C Dimensions 58...
Страница 67: ...Appendix C Dimensions 59...
Страница 68: ...Appendix C Dimensions 60...
Страница 70: ...Index 62...