Chapter 6: Operation (Profibus Units)
45
Setting an Address
Example for address 5 in Profibus mode:
ADDRESS
B
0
1
2
3
4
5
6
A
Switch position =
Mode A
If the mode switch sets A mode, the device operates as an analog device. PROFIBUS may be
used for monitoring and the bus address will be used, which was set previously in bus mode. The
address switches in analog mode define the analog zeroing mode.
Example for setting analog mode and zero mode 3:
ADDRESS
B
0
1
2
3
4
5
6
A
Switch position =
Zero Modes
0
Offset Value is always Zero
1
Offset Value (USER_ZERO) stored in the device is not changed.
2
If the valve is off (VALVE_OVERRIDE == FLOW_OFF) for at least 10 sec. an AUTOZERO
is performed.
3
10 sec. after reset, AUTOZERO is performed as long as valve is off. (value stored)
4
10 sec. after reset, AUTOZERO is performed if flow is smaller than 10% of FS. (value
stored)
Содержание 1579A
Страница 8: ...Table of Contents 1579A 579A viii This page intentionally left blank...
Страница 12: ...Safety Information 1579A 579A 12 This page intentionally left blank...
Страница 16: ...Chapter 1 General Information 1579A 579A 16 This page intentionally left blank...
Страница 20: ...Chapter 2 Shipment 1579A 579A 20 This page intentionally left blank...
Страница 28: ...Chapter 3 Connectors and Control Elements 1579A 579A 28 This page intentionally left blank...
Страница 38: ...Chapter 5 Operation Analog Units 1579A 579A 38 This page intentionally left blank...
Страница 70: ...Chapter 10 Maintenance 1579A 579A 70 This page intentionally left blank...
Страница 74: ...Appendix A Product Specifications 1579A 579A 74 This page intentionally left blank...
Страница 82: ...Appendix C Gas Correction Factors 1579A 579A 82 This page intentionally left blank...
Страница 84: ...Appendix C Gas Correction Factors 1579A 579A 84 This page intentionally left blank...
Страница 86: ...Next page Health and Safety Form Contact MKS at the web or at any MKS location if the form is missing...