Operating the unit
22
Operating instructions
2. Press the "On Off" button.
Heating switches off.
The "Heating" indicator light goes out.
Unit cools down.
The unit is off.
4.3 Performing basic control setting
The control can be set only on models with EcoControl.
Changing parameters that are not indicated can lead to the
warranty possibly becoming void.
MKN does not assume any responsibility or liability for damage,
which is caused by unauthorized changing of parameters.
Claims against MKN that are due to this can not be upheld, not
even within the scope of the guarantee or warranty.
The basic setting for the unit is preset at the time of delivery. The
values can be changed. For an overview of the settings, see the
following list.
EcoControl basic control setting - Level 1: Bratt pan
Setting
Parameter
s
Standard
value
Range of
adjustment
Explanation
Program number
Id
001
1—255
Without function
Automatic process
start
APS
1
0
Deactivated, signal sounds
1
Activated, no signal at process start
Without function
dt_
---
---
Without function
Without function
tc_
---
---
Without function
Altitude
H__
0
0—30
Altitude in 100 m increments
Set the temperature
unit
F__
0
0
Degrees Celsius ( °C)
1
Degrees Fahrenheit ( °F)
Process start at
overtemperature
PSO
0
0
Process start only if set temperature
reached
1
Process start even if temperature is above
set value
2021441-20ABBE-B
Содержание O7EMPF Series
Страница 6: ...Directory of contents 6 Operating instructions 2021441 20ABBE B...