Description of the unit
15
Installation instructions
Basic control setting (Advanced)
Basic setting
Parameter
s
Standard
value
Adjustment
range
Explanation
Generator operation
45
0
0 = No
If a generator is used to supply electricity
1 = Yes
Vapour elimination
48
1
0 = Low
Sets the vapour elimination level
1 = Normal
2 = High
Time format
675
0
0 = 24 h
Sets the 12 h or 24 h time format
1 = 12 h
Format for cooking
program times
676
0
0 = hh:mm
1 = mm:ss
2 = Automatic
Display format for cooking program times