Connecting the unit
36
Installation instructions
Professional qualification for wastewater specialist
Installation work on wastewater lines and the unit may only be carried
out by a wastewater specialist from the specialist company assigned
to the work.
6.6.1 Connecting the wastewater line to a permanent connection
d
a
f
e
c
b
Image: Wastewater line with vacuum breaker to a permanent connection
a Sewer system
d Pipe clamp
b Wastewater line
e Wastewater connection
c Vacuum breaker
f Sewer system waste trap
A vacuum breaker must be installed in the wastewater line.
Requirement
Wastewater line complies with the specifications (see "Equipment
and connection data")
1. Install the wastewater line up to the connection at the sewer
system.
2. Secure the wastewater line with pipe clamps.
3. Fill the waste trap on the unit with tap water.
4. Fill out the Commissioning report.
4127002--0AIBE-C