122
-
●
Inspection of resistance value of
dischargepipe sensor.
Remove the connector and check the resis-
tance value. See the section of sensor char-
acteristics on page 116.
●
Inspection of electronic expansion valve
To test if there is voltage.
(Voltage is only applied to the electronic expansion valve when the
valve angle is being changed.)
Red to white
Red to Orange
Brown to yellow
Brown to blue
If the expansion valve does not operate as shown above, it
is defective.
}
(When tester probes
are inverted, the
reading should be
approx. 10~20
Ω
.)
●
Inspection of diode stack (DS1)
Tester probe
Normal
condition
,
+ (OR)
+ (OR)
~ (BL)
~ (GR)
.
~ (BL)
~ (GR)
– (BK)
– (BK)
●
Inspection of inductor conductivity
Remove the connector and check for conduc-
tivity. It must be conductive.
●
Inspect power
transistor.
Remove the fasten
terminal and test out-
put voltage.
Check fuse. There should be conductivity.
CAUTION – HIGH VOLTAGE
(ii) Outdoor unit inspection points
High voltage is produced in the control box. Don't touch
electrical parts in the control box for 5 minutes after the
unit is stopped.
S
SRC22ZEV-S
¡
Power source and serial signal inspection
L
to
N
: AC220V
1
to
2
: AC220V
2
to
3
:
Normal if the voltage oscillates between DC 0 and approx. 12V
Normal if there is approximately DC 5 V 10 seconds
after the power supply is turned on.
BK
Color symbol
BL
OR
Y/G
Black
Blue
Orange
Yellow/Green
WH
White
RD
Red
GR
Green
Y
Yellow
2/N
1
3
Y/GN
BK
WH
RD
TB
DC-P
DC-N
AF-L2
AF-L1
AC.L
AC.N
Q1
Power
transistor
250V
F
AC.N
AC.L
P
N
U
V
W
RD
WH
BK
GR
GR
BL
BL
L
N1
N2
P2
IC2
+
-
DS1
L
OR
OR
P_1
N_1
Switching
power circuit
BK
RD
RD
BK
+
+
+
P_1
N_1
1
2
20A
WH
Y/G
BK
N-1
G3
L-1
Power Source
1 Phase
220V 50Hz
Indoor unit
L
N
Y/G
G2
HEATER
250V 2A
F
4
6
F1
250V 2A
C1
C1
C1
F
250V 20A
PWB1
PWB2
PWB3
CNT
CNG
CNH
CNG
CNH
CNG
CND
CNB
CNJ
CNO
CNI
CNC
FMo
CM
20S
EEV
Th4
Th5
Th6
RL
Содержание SRK10CES
Страница 2: ...TECHNICAL MANUAL...
Страница 204: ...202 MEMO...
Страница 208: ...CRAE0171 10 11 12 13 20 21 24 22 23 25 17 18 16 14 15 19 7 8 6 5 1 9 2 4 3 HEAT EXCH CONTROL 206...
Страница 213: ...211...
Страница 214: ...CRAE0168 21 1 9 3 8 7 6 5 4 2 23 11 10 13 17 12 15 14 16 18 19 20 22 24 25 26 27 29 28 HEAT EXCH CONTROL 212...
Страница 218: ...CRAE0141 1 4 5 6 7 8 10 11 12 13 14 15 19 20 21 25 26 23 24 22 16 9 2 3 18 17 HEAT EXCH CONTROL 216...
Страница 222: ...CRAE0141 1 4 5 6 7 8 10 11 12 13 14 15 19 20 21 25 26 23 24 22 16 9 2 3 18 17 HEAT EXCH CONTROL 220...
Страница 227: ...225...
Страница 228: ...CRAE0166 21 1 9 3 8 7 6 5 4 23 11 2 10 13 17 12 15 14 16 18 19 20 22 24 25 26 27 29 28 HEAT EXCH CONTROL 226...
Страница 233: ...231...
Страница 234: ...CRAE0166 21 1 9 3 8 7 6 5 4 23 11 2 10 13 17 12 15 14 16 18 19 20 22 24 25 26 27 29 28 HEAT EXCH CONTROL 232...
Страница 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Страница 240: ...05 0 CRBE0207 2 12 6 1 7 14 3 24 16 19 4 9 10 5 11 11 13 15 8 18 17 20 23 21 22 PANEL FAN ASSY 238...
Страница 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Страница 246: ...CRBE0190 1 2 4 3 5 6 7 8 13 10 14 15 12 11 9 GAS LIQ 18 19 20 17 21 16 CONTROL ASSY HEAT EXCH CONTROL 244...
Страница 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Страница 250: ...CRBE0191 1 3 4 5 2 6 7 8 10 13 9 12 11 15 14 LIQ GAS CONTROL ASSY 17 18 16 HEAT EXCH CONTROL 248...
Страница 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Страница 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Страница 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...