7 - 26 7 - 26
MELSEC-Q
7 PARAMETER SETTING
7.4.2 MODBUS
®
device assignment parameters details
Address
Parameter Name
Setting Range
Default
Value
0900
H
(2304)
Device code
0000
H
: Device code not assigned
Other than 0000
H
: Device code
0901
H
(2305)
Head device number
0000
H
to FFFF
H
0902
H
(2306)
Head coil number
0000
H
to FFFF
H
0903
H
(2307)
Coil assignment 1
Assignment points
0000
H
to FFFF
H
(*1)
0904
H
to 093F
H
(2308 to 2367)
Coil
Coil assignment 2 to
16
(Same as in coil assignment 1)
0940
H
(2368)
Device code
0000
H
: Device code not assigned
Other than 0000
H
: Device code
0941
H
(2369)
Head device number
0000
H
to FFFF
H
0942
H
(2370)
Head input number
0000
H
to FFFF
H
0943
H
(2371)
Input assignment 1
Assignment points
0000
H
to FFFF
H
(*1)
0944
H
to 097F
H
(2372 to 2431)
Input
Input assignment 2
to 16
(Same as in input assignment 1)
0980
H
(2432)
Device code
0000
H
: Device code not assigned
Other than 0000
H
: Device code
0981
H
(2433)
Head device number
0000
H
to FFFF
H
0982
H
(2434)
Head input register
number
0000
H
to FFFF
H
0983
H
(2435)
Input register
assignment 1
Assignment points
0000
H
to FFFF
H
(*1)
0984
H
to 09BF
H
(2436 to 2495)
Input register
Input register
assignment 2 to 16
(Same as in input register assignment 1)
09C0
H
(2496)
Device code
0000
H
: Device code not assigned
Other than 0000
H
: Device code
09C1
H
(2497)
Head device number
0000
H
to FFFF
H
09C2
H
(2498)
Head holding register
number
0000
H
to FFFF
H
09C3
H
(2499)
Holding register
assignment 1
Assignment points
0000
H
to FFFF
H
(*1)
09C4
H
to 09FF
H
(2500 to 2559)
Holding
register
Holding register
assignment 2 to 16
(Same as in holding register assignment 1)
*1: When the intelligent function switch 2 - MODBUS
R
device assignment parameter starting method (Bit
1) setting is "Start with the default parameters" (OFF), the default assignment parameters are used.
The default parameter values are displayed on the MODBUS
R
device assignment parameter setting
screen of GX Configurator-MB.
Refer to Section 7.4.3 for the default assignment parameters.
POINT
With the intelligent function module switch, turn ON the MODBUS
R
device
assignment parameter starting method. (Refer to Section 6.6)
If this switch is set to OFF, the operation will proceed based on the default
assignment parameters. (Refer to Section 7.4.3)
Содержание QJ71MT91
Страница 1: ......
Страница 2: ......
Страница 278: ...App 1 App 1 MELSEC Q APPENDICES APPENDICES Appendix 1 External Dimensions Unit mm in 27 4 1 08 90 3 54 98 3 86 APP ...
Страница 291: ......
Страница 292: ......