2 - 16
2 SYSTEM CONFIGURATION
2.4 General Specifications
General specifications of the Motion controller are shown below.
Item Specification
Operating ambient temperature
0 to 55°C (32 to 131°F)
Storage ambient temperature
-25 to 75°C (-13 to 167°F)
(Note-3)
Operating ambient humidity
5 to 95% RH
,
non-condensing
Storage ambient humidity
5 to 95% RH
,
non-condensing
Frequency
Acceleration
Amplitude
Sweep
count
5 to 9Hz
——
3.5mm
(0.138inch)
Under intermittent
vibration
9 to 150Hz
9.8m/s
2
——
5 to 9Hz
——
1.75mm
(0.069inch)
Vibration resistance
Under continuous
vibration
9 to 150Hz
4.9m/s
2
——
10 times each
in X, Y, Z
directions
(For 80 min.)
Shock resistance
147m/s
2
, 3 times in each of 3 directions X, Y, Z
Operating ambience
No corrosive gases
Operating altitude
2000m(6561.68ft.) or less
Mounting location
Inside control panel
Overvoltage category
(Note-1)
II or less
Pollution level
(Note-2
)
2 or less
(Note-1) : This indicates the section of the power supply to which the equipment is assumed to be connected between the
public electrical power distribution network and the machinery within premises.
Category applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
(Note-2) : This index indicates the degree to which conductive material is generated in terms of the environment in which
the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing
must be expected occasionally.
(Note-3) : Do not use or store the Motion controller under pressure higher than the atmospheric pressure of altitude 0m.
Doing so can cause an operation failure.
CAUTION
The Motion controller must be stored and used under the conditions listed in the table of
specifications above.
When not using the module for a long time, disconnect the power line from the Motion controller
or servo amplifier.
Place the Motion controller and servo amplifier in static electricity preventing vinyl bags and store.
When storing for a long time, please contact with our sales representative.
Also, execute a trial operation.
Содержание Q170MCPU
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 81: ...2 54 2 SYSTEM CONFIGURATION MEMO ...
Страница 135: ...5 10 5 START UP PROCEDURES MEMO ...
Страница 171: ...7 6 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 225: ...APP 54 APPENDICES MEMO ...
Страница 228: ......