2 - 46
2 SYSTEM CONFIGURATION
(6) Connection examples of manual pulse generator
Connection of manual pulse generator Connection of manual pulse generator
(Voltage-output/Open-collector type) (Differential-output type)
SG
SG
Q173DPX
SG
P5
Signal name
A
A
B
0V
5V
SG
P5
A
B
0V
5V
B
Manual pulse
generator side
FG
FG
SG
Shield
: 1 to 3
HA
HB
Q173DPX
Manual pulse
generator side
Signal name
: 1 to 3
HA P
HA N
HB P
HB N
HPSEL
(Note-2)
(Note-1)
(Note-1)
:Twisted pair cable
:Twisted pair cable
Shield
(Note-1) : The 5V(P5)DC power supply from the Q173DPX must not be connected if a separated
power supply is used as the Manual pulse generator/Incremental synchronous
encoder power supply.
Use a 5V stabilized power supply as a separated power supply. Any other power supply
may cause a failure.
(Note-2) : Connect HPSEL
to the SG terminal if the manual pulse generator (differential-output
type)/incremental synchronous encoder is used.
CAUTION
If a separate power supply is used as the manual pulse generator/incremental synchronous
encoder power supply, use a 5V stabilized power supply. Any other power supply may cause a
failure.
Always wire the cables when power is off. Not doing so may damage the circuit of modules.
Wire the cable correctly. Wrong wiring may damage the internal circuit.
Содержание Q170MCPU
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 81: ...2 54 2 SYSTEM CONFIGURATION MEMO ...
Страница 135: ...5 10 5 START UP PROCEDURES MEMO ...
Страница 171: ...7 6 7 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 225: ...APP 54 APPENDICES MEMO ...
Страница 228: ......