3 - 10
3 DESIGN
(b) The forced stop of all servo amplifiers is possible in a lump by using the
forced stop input of input modules. After forced stop, the forced stop factor is
removed and the forced stop canceled.
(The servo error detection signal does not turn on with the forced stop.)
The forced stop input can be set by allocation of the device number in the
parameter setting of system setting. When the device is used, apply 24VDC
voltage on EMI terminal and invalidate the forced stop input of EMI terminal.
The wiring example that uses the forced stop input of input module (QX10)
is shown below.
R
R
R
TB17
TB1
TB16
100VAC
LED
QX10
Internal
circuit
Forced stop
<Input module QX10>
(Note): The forced stop input can be set in the system settings.
Xn
QX10
COM
AC100V
Q170M
CPU
EMI.COM
EMI
+24V
24G
Forced stop
24VDC
power supply
(c) It is also possible to use the forced stop signal of the servo amplifier.
Refer to manual of the servo amplifier about servomotor capacity.
Operation status of the emergency stop and the forced stop are as follows.
Item
Operation of
the signal ON
Remark
Emergency stop
Shut off the power supply to the external servo amplifier
by external circuit, make the servomotor stopped.
Forced stop
Servo OFF
The servomotor is stopped according to the stop
instruction from Motion controller to the servo amplifier.