6 - 50
6 - 50
6. HOW TO COMMUNICATE WITH ID TAGS
6.4.10 Control number of writes
The Control Number of Writes program is a program for writing to an ID tag the number
of writes to EEPROM-type ID tags, and assessing whether or not the number of writes
of the ID tag has been exceeded.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Buffer Memory Name
Setting Contents
U0
\
G0
Command code specification
area (CH1)
H8 (Control Number of Writes)
U0
\
G3
Head address specification
area (CH1)
K10 (Address: 10)
U0
\
G5
Command option specification
area (CH1)
K5 (Number of times added: 5)
(b) Devices used by user
1. External inputs (commands/data)
Device Application
M1090
Control Number of Writes of ID Tag command
M1091
Cancel Control Number of Writes of ID Tag command
2. External outputs (verification)
Device Application
M1092
Normal completion during Control Number of Writes of ID Tag
M1093
Module error during Control Number of Writes of ID Tag
D1090
Error details storage during Control Number of Writes of ID Tag
D1091 to D1092
Number of writes calculation result storage during Control Number of
Writes of ID Tag