6. HOW TO COMMUNICATE WITH ID TAGS
(5) Intelligent function module switch setting
The Intelligent function module switch setting of the remote I/O module at remote
I/O station is as follows.
When use intelligent function module switch setting in the default state, the
parameter setting is not necessary.
Slot Type
Module
name Switch1 Switch 2 Switch 3 Switch 4 Switch 5
0
Remote
I/O
Remote
I/O QJ72LP25
1 0(*-0)
INTERI
EQ-V680D1
0004
0000
0000 0000
0000
2
1(*-1)
INPUT
QX41
3
2(*-2)
OUTPUT
QY41P
Switch Setting Items
b15
~
b3 b2
b1
B0
Switch1
0
:
Fixed
Write protect setting
0(OFF)
:
Enable
1(ON)
:
Disable
ID tag communication speed setting
0(OFF)
:
Standard mode
1(ON)
:
High-speed mode
Write verify setting
0(OFF)
:
Execute
1(ON)
:
Do not execute
b15
~
b3 b2
b1
b0
Switch
2
0
:
Fixed
Enable ch.2 Test mode
0(OFF)
:
Enable
1(ON)
:
Disable
Enable ch.1 Test mode
0(OFF)
:
Enable
1(ON)
:
Disable
Enable Y contact test request
0(OFF)
:
Enable
1(ON)
:
Disable
(6) Output mode at the time of the CPU error
The output mode at the time of the CPU error of the remote I/O module at remote
I/O station is as follows.
Output mode at the time of the CPU error
Clear
Items are set in GX Developer.
Items are set in GX Developer.