FX3G INSTALLATION MANUAL
3
1. INTRODUCTION
This manual describes the part names, dimensions, mounting, cabling
and specifications for the product. Before use, read this manual
and manuals of relevant products fully to acquire proficiency in the
handling and operating the product. Make sure to learn all the product
information, safety information, and precautions.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each company.
Effective December 2009
Specifications are subject to change without notice.
© 2008 Mitsubishi Electric Corporation
1.1 AVAILABLE MODELS
The main unit incorporates a CPU, memory, input and output terminals
and power supply.
FX3G–
hh
M
h
/
h
Model
No. of Input/Output Points
Input
Type
Output
Type
Connection
Total No.
Points
Input
Points
Output
Points
AC Power Supply Common to 24VDC Sink and Source Input
FX3G-14MR/ES 14 (16) *1
8
6(8) *1
24VDC
(sink/
source)
Relay
Terminal
block
FX3G-24MR/ES 24 (32) *1 14(16) *1 10(16) *1
FX3G-40MR/ES 40
24
16
FX3G-60MR/ES 60 (64) *1 36(40)*1 24
Model
No. of Input/Output Points
Input
Type
Output
Type
Connection
Total No.
Points
Input
Points
Output
Points
DC Power Supply Common To 24V DC Sink and Source Input
FX3G-14MR/ES 14 (16) *1
8
6(8) *1
24VDC
(sink/
source)
Transis-
tor sink
Terminal
block
FX3G-24MR/ES 24 (32) *1 14(16) *1 10(16) *1
FX3G-40MR/ES 40
24
16
FX3G-60MR/ES 60 (64) *1 36(40)*1 24
1.2 CAUTION
Safety Precaution (Read these precautions before use.) This manual
classifies the safety precautions into two categories:
DANGER
and
CAUTION
.
DANGER
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
CAUTION
may also cause severe injury. It is important to follow all precautions for
personal safety.
DANGER:
STARTUP AND MAINTENANCE PRECAUTIONS
• Do not touch any terminal while the PLC’s power is on. Doing so
may cause electric shock or malfunctions.
• Before cleaning or retightening terminals externally cut off all phases
of the power supply. Failure to do so may cause electric shock
• Use the battery for memory backup correctly as described in this
manual.
Use the battery only for the specified purpose.
Connect the battery correctly.
Do not charge, disassemble, heat, put in fire, short-circuit, connect
reversely, weld, swallow or burn the battery, or apply excessive
forces (vibration, impact, drop, etc.) to the battery.
Do not store or use the battery at high temperatures or expose to
direct sunlight.
Do not expose to water, bring near fire or touch liquid leakage or
other contents directly.
Incorrect handling of the battery may cause heat excessive
generation, bursting, ignition, liquid leakage or deformation, and
lead to injury, fire or failures and malfunctions of facilities and
other equipment.
• Before modifying or disrupting the program in operation or running
the PLC, carefully read through this manual to ensure the safety
of the operation. An operation error may damage the machinery or
cause accidents.
CAUTION:
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device. When
disposing of batteries, separate them from other waste according to
local regulations.
CAUTION:
TRANSPORT AND STORAGE PRECAUTIONS
• When transporting the FX3G Series PLC incorporating the optional
battery, turn on the PLC before shipment, confirm that the battery
mode is set using a parameter and the ALM LED is OFF, and check
the battery life. If the PLC is transported with the ALM LED on or the
battery exhausted, the battery-backed data may be unstable during
transportation.
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 3.1. Failure to do
so may cause failures in the PLC. After transportation, verify the
operations of the PLC.
• When transporting lithium batteries, follow required transportation
regulations.
Series Name
Total number of input
and output points
Main Unit
Power supply, Input/output type: Connection on terminal block
R/ES: AC power supply/24VDC (sink/source) input/relay
output
T/DS: DC power supply/24VDC (sink/source) input/
Transistor (sink) output