![Mitsubishi FX-1PG Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/mitsubishi/fx-1pg/fx-1pg_user-manual_1809671063.webp)
M8002
FNC 79
TO
K 0
K 19
K50000
K 1
D
Writing of set position
(At forward)
Writing of set position
(At reverse)
Writing of operating speed
M28
M34
M28
M31
Positioning
completed
flag
D11,D10 = K0
Current value = 0
D11,D10 = K10000
Current value = 10000
M8002
FNC 79
TO
K 0
K 17
K10000
K 1
D
FNC 79
TO
K 0
K 17
K-
10000
K 1
D
X000
X001
X002
X004
X005
X006
M8000
M 7
M 6
M 5
M 4
M 1
M 2
M 3
M 0
Error reset
STOP
Forward pulsestop
Reverse pulse stop
JOG+ operation
JOG- operation
Homeposition return start
Relative position
X003
X007
M 8
Single speed positioning start
T0
P
P
10
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT
EXAMPLES PROGRAM
10-6