![Mitsubishi FX-1PG Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/mitsubishi/fx-1pg/fx-1pg_user-manual_1809671060.webp)
<Setting of buffer memory (BFM)>
BFM
Item
Set value
Note
BFM
Item
Set value
Note
#0
Pulserate
8192 *1
PLS/REV
#16
−
−
#2, #1
Feed rate
1000
µ
m/REV
#18, #17 Set position (
Ι
)
10000
mm
#3
Parameters
b1:1, b0:0
Combined
system
#20, #19 Operating speed (
Ι
)
50000
Hz
b1, b0 System of units
#22, #21 Set position (
ΙΙ
)
−
b5, b4 Position data multiplication
b5:1, b4:1
10
3
#24, #23 Operating speed (
ΙΙ
)
−
b8
Pulseoutput format
0
Forward pulse
#25
Operation command
M0
b9
Rotation direction
0
Thecurrent
valueincrease
b0
Error reset
b10 Home position return direction
0
Thecurrent
value decrease
b1
STOP
M1
b12 DOG input polarity
0
DOG input ON
b2
Forward pulsestop
M2
b13 Count start timing
1
Rear end of
DOG input
b3
Reverse pulse stop
M3
b14 STOP input polarity
0
Stops because
of turning on
b4
JOG+
M4
b15 STOP input mode0
The remainder
distancedrive
b5
JOG-
M5
#5, #4
Maximum speed
50000
b6
Home position return start
M6
#6
Bias speed
0
b7
Address
b7=1 M7
Relative
#8, #7
JOG speed
10000
b8~
b12
Singlespeed positioning start
b8=M8
b12~b9
Unused
#10, #9
Home position return speed
(high speed)
10000
#27, #26 Current position
D11, D10
mm
#11
Home position return speed
(creep speed)
1500
#28
Status
M31~M20
#12
Number of zero point signals for home
position return
10
#29
Error codeD20
#14, #13 Homeposition
0
#30
Model code
D12
#15
Acceleration / deceleration time
100
ms
#31
−
−
*1: This example is described as an example of servo mode by Mitsubishi Electric Corporation amplifier MR-J2.
The value is different according to the connected servo amplifier.
10
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT
EXAMPLES PROGRAM
10-3