9.3
Example of External Connection (MR-C Servo Amplifier)
*1 To release the alarm status, turn off the power, remove the cause of the alarm, then turn on the power again.
*2 The failure (ALM) signal is turned on in the normal status. When an alarm has occurred (the ALM signal is turned off),
stop pulsegeneration from thePGU using theprogram in thePC.
SG
FX
,
FX
2C,
FX
2N
Series PC
X10
X11
X12
Positioning
completed
Servo failure
PF
3
ALM
2
LSP
LSN
Forward
limit
15
14
SON
17
SG
12
L1
L2
U
V
W
To servo motor
RA1
RA2
*2
MR-C
¨
A
MR-C
¨
A1
Servo amplifier
Servo ON
Parameter Pr16 is set
to "position servo".
MR-C
¨
A
MR-C
¨
A1
: Single-phase,
200V AC
: Singlephase,
100V AC
RUN terminal is not provided
in FX
2N
, so this wiring is not
required in FX
2N
.
*1
RA1 RA2
24V DC power supply
0.2A or more
*3
Reverse
limit
SG terminal is not provided in
FX
2N
, so this wiring is not
required in FX
2N
.
L
N
24V
RUN
X0
X1
X2
X3
X4
X5
X6
X7
STOP
RUN
Error
reset
Forward
limit Reverse
limit
JOG+
JOG-
Home
position
Start
S/S
0V
Sensor
power supply
24V DC
9
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT
EXTERNAL CONNECTION EXAMPLES
9-5