![Mitsubishi FX-1PG Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/mitsubishi/fx-1pg/fx-1pg_user-manual_1809671026.webp)
[b11]
When b11 = 0
→
1: External command
positioning operation start
External command positioning operation is
performed. The rotation direction is determined
by the sign of the speed command.
For the details, see Section 6.3.
[b12]
When b12 = 1: Variable speed operation
Variable speed operation is performed.
For the details, see Section 6.4.
< Operation command data transfer method >
X000
X001
X002
X003
X004
X005
X006
Start
X007
M8000
M 2
M 3
M 4
M 5
M 6
M 7
M 8
M 9
M 1
M 0
M 10
M 11
M 12
M8000
RUN
monitor
Error reset
(M15~M 0)
→
BFM #25 (b15~b 0)
Stop command
Forward pulsestop
Reverse pulse stop
Jog+ operation
Jog- operation
Homeposition
return start
Relative/absolute
position
Single-speed
positioning
Interrupt single-
speed positioning
Two-speed
positioning
External command
positioning
Variable speed
operation
TO
K 0
K25
K4M0
K 1
Set only
oneof
them to
ON.
(Normally
closed contact)
(Normally
closed contact)
5
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT
BFM LIST
5-11