22
INVERTER SETTING
Pr. 340
Setting
Pr. 79
Setting
Operation Mode at Power on or Power
Restoration
Operation Mode Switchover
0
(initial
value)
0 (initial
value)
External operation mode
Switching among the external, PU, and NET operation mode is
enabled
*1
1
PU operation mode
PU operation mode fixed
2
External operation mode
Switching between the external and Net operation mode is enabled
Switching to the PU operation mode is disallowed
3, 4
External/PU combined operation mode
Operation mode switching is disallowed
6
External operation mode
Switching among the external, PU, and NET operation mode is enabled
while running.
7
X12 (MRS) signal ON..... external operation mode Switching among the external, PU, and NET operation mode is enabled
*1
X12 (MRS) signal OFF ... external operation mode External operation mode fixed (Forcibly switched to external
operation mode.)
1, 2
*2
0
NET operation mode
Same as when
Pr. 340
= "0"
1
PU operation mode
2
NET operation mode
3, 4
External/PU combined operation mode
6
NET operation mode
7
X12 (MRS) signal ON .... NET operation mode
X12 (MRS) signal OFF ... external operation mode
10, 12
*2
0
NET operation mode
Switching between the PU and NET operation mode is enabled
*3
1
PU operation mode
Same as when
Pr. 340
= "0"
2
NET operation mode
NET operation mode fixed
3, 4
External/PU combined operation mode
Same as when
Pr. 340
= "0"
6
NET operation mode
Switching between the PU and NET operation mode is enabled while running
*3
7
External operation mode
Same as when
Pr. 340
= "0"
*1 Operation mode can not be directly changed between the PU operation mode and network operation mode.
*2 The
Pr. 340
settings "2, 12" are mainly used for communication operation using the inverter RS-485 terminal.
When a value other than "9999" (selection of automatic restart after instantaneous power failure) is set in
Pr. 57 Restart coasting time
, the
inverter will resume the same operation state which was in before after power has been restored from an instantaneous power failure.
When
Pr.340
= "1, 10", a start command turns off if power failure has occurred and then restored during a start command is on.
*3 Operation mode can be changed between the PU operation mode and network operation mode with
of the operation panel (FR-