67
DETAILS OF INPUT AND
OUTPUT SIGNALS
7
*
When torque command (FR-A700 series only) is given, values of reply code 1 below are changed.
(when values other than 14, 18, (118) are set in
Pr.544
)
When
Pr.544
= 14, 18, (118), the above 4 bit of the reply code 1 is reply code to the torque command and the lower 4
bit is to the frequency command.
Example) The error code is H0030 when the torque command value is outside the setting range.
Bit15
Bit0
Reply code2
Reply code1
Reply code
corresponds to the
torque command
Reply code
corresponds to the
frequency command
Bit15
Bit0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
Reply code corresponds to
the torque command