Control circuit specifications
2
*1
Set
Pr. 73
,
Pr. 267
, and a voltage/current input switch correctly, then input an analog signal in accordance with the setting.
Applying a voltage signal with voltage/current input switch ON (current input is selected) or a current signal with switch OFF (voltage input is
selected) could cause component damage of the inverter or analog circuit of signal output devices.
*2
Refer to Chapter 4 of
the Instruction Manual (Applied).
(2) Output signals
Fr
eq
ue
ncy
s
et
tin
g
10E
Frequency
setting power
supply
When connecting the frequency setting potentiometer at an initial
status, connect it to terminal 10.
Change the input specifications of terminal 2 when connecting it
to terminal 10E.
(Refer to Pr. 73 Analog input selection in Chapter 4 of
the Instruction Manual (Applied).)
10VDC
Permissible load
current 10mA
*2
10
5VDC
Permissible load
current 10mA
2
Frequency
setting
(voltage)
Inputting 0 to 5VDC (or 0 to 10V, 0 to 20mA) provides the
maximum output frequency at 5V (10V, 20mA) and makes input
and output proportional. Use
Pr. 73
to switch from among input 0
to 5VDC (initial setting), 0 to 10VDC, and 0 to 20mA.
Set the voltage/current input switch in the ON position to select
current input (0 to 20mA).
Voltage input:
Input resistance
10k
Ω
± 1k
Ω
Maximum
permissible voltage
20VDC
Current input:
Input resistance
245
Ω
± 5
Ω
Maximum
permissible current
30mA
4
Frequency
setting
(current)
Inputting 4 to 20mADC (or 0 to 5V, 0 to 10V) provides the
maximum output frequency at 20mA makes input and output
proportional. This input signal is valid only when the AU signal is
ON (terminal 2 input is invalid).
Use
Pr. 267
to switch from among input 4 to 20mA (initial setting),
0 to 5VDC, and 0 to 10VDC.
Set the voltage/current input switch in the OFF position to select
voltage input (0 to 5V/0 to 10V).
(Refer to Chapter 4 of
the Instruction Manual (Applied).)
Use
Pr.
858
to switch terminal functions.
1
Frequency
setting
auxiliary
Inputting 0 to ±5 VDC or 0 to ±10VDC adds this signal to terminal
2 or 4 frequency setting signal. Use
Pr.
73
to switch between the
input 0 to ±5VDC and 0 to ±10VDC (initial setting).
Use
Pr. 868
to switch terminal functions.
Input resistance
10k
Ω
± 1k
Ω
Maximum
permissible voltage
± 20VDC
5
Frequency
setting
common
Common terminal for frequency setting signal (terminal 2, 1 or 4)
and analog output terminal AM. Do not earth (ground).
--------------------
------
Ty
p
e Terminal
Symbol
Terminal
Name
Description
Rated
Specifications
Refer to
page
Re
la
y
A1,
B1,
C1
Relay output 1
(alarm output)
1 changeover contact output indicates that the inverter
protective function has activated and the output stopped.
Fault: No conduction between B and C (conduction between A
and C)
Normal: Conduction between B and C (No conduction between
A and C)
Contact capacity:
230VAC 0.3A
(Power factor=0.4)
30VDC 0.3A
A2,
B2,
C2
Relay output 2
1 changeover contact output
Ty
p
e Terminal
Symbol
Terminal
Name
Description
Rated
Specifications
Refer to
page
Voltage/current
input switch
2
4
switch1
switch2