124
Te
rminal assignm
ent
of
out
put
t
e
rm
inal
190
RUN terminal function
selection
1
0
0 to 6, 8,
10 to 20,
25 to 28,
30 to 36, 39,
41 to 47,
64, 70, 84,
90 to 99,
100 to 106,
108,
110 to 116,
120,
125 to 128,
130 to 136,
139,
141 to 147,
164, 170,
184,
190 to 199,
9999
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
2, 102: Instantaneous power failure/undervoltage
(IPF)
3, 103: Overload warning (OL)
4, 104: Output frequency detection (FU)
5, 105: Second output frequency detection (FU2)
6, 106: Third output frequency detection (FU3)
8, 108: Electronic thermal O/L relay pre-alarm (THP)
10, 110:PU operation mode (PU)
11, 111: Inverter operation ready (RY)
12, 112:Output current detection (Y12)
13, 113:Zero current detection (Y13)
14, 114:PID lower limit (FDN)
15, 115:PID upper limit (FUP)
16, 116:PID forward/reverse rotation output (RL)
17, —: Electronic bypass MC1 (MC1)
18, —: Electronic bypass MC2 (MC2)
19, —: Electronic bypass MC3 (MC3)
20, 120:Brake opening request (BOF)
25, 125:Fan fault output (FAN)
26, 126:Heatsink overheat pre-alarm (FIN)
27, 127:Orientation complete (ORA) *
28, 128:Orientation fault (ORM) *
30, 130:Forward rotation output (Y30) *
31, 131:Reverse rotation output (Y31) *
32, 132:Regenerative status output (Y32) *
33, 133:Operation ready 2 (RY2)
34, 134:Low speed output (LS)
35, 135:Torque detection (TU)
36, 136:In-position (Y36) *
39, 139:Start time tuning completion (Y39)
41, 141:Speed detection (FB)
42, 142:Second speed detection (FB2)
43, 143:Third speed detection (FB3)
44, 144:Inverter running 2 (RUN2)
45, 145:Inverter running and start command is ON
(RUN3)
46, 146:During deceleration at occurrence of power
failure (retained until release) (Y46)
47, 147:During PID control activated (PID)
64, 164:During retry (Y64)
70, 170:PID output interruption (SLEEP)
84, 184:Position control preparation ready (RDY) *
90, 190:Life alarm (Y90)
91, 191:Fault output 3 (power-off signal) (Y91)
92, 192:Energy saving average value updated timing
(Y92)
93, 193:Current average monitor signal (Y93)
94, 194:Fault output 2 (ALM2)
95, 195:Maintenance timer signal (Y95)
96, 196:Remote output (REM)
97, 197:Alarm output 2 (ER)
98, 198:Alarm output (LF)
99, 199:Fault output (ALM)
9999: No function
0 to 99: Positive logic
100 to 199: Negative logic
* Available only when used with the FR-A7AP/FR-A7AL
(option).
191
SU terminal function
selection
1
1
192
IPF terminal function
selection
1
2
193
OL terminal function
selection
1
3
194
FU terminal function
selection
1
4
195
ABC1 terminal function
selection
1
99
0 to 6, 8,
10 to 20,
25 to 28,
30 to 36, 39,
41 to 47, 64,
70, 84, 90,
91,
94 to 99,
100 to 106,
108,
110 to 116,
120,
125 to 128,
130 to 136,
139,
141 to 147,
164, 170,
184, 190,
191, 194 to
199, 9999
196
ABC2 terminal function
selection
1
9999
—
232 to 239
Refer to
Pr. 4 to Pr. 6
.
240
Refer to
Pr. 72
.
241
Refer to
Pr. 125
and Pr. 126
.
242, 243
Refer to
Pr. 73
.
Func
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Re
la
te
d
p
ara
m
e
te
rs