94
OCH771
[Contact demand capacity] (Request code : " 61")
Data display
0 0 0
Setting content
[External input state] (Request code : "62")
Data display
0 0 0
Input state
Input state
: Input position
Display Contact demand
Silent mode
Spare 1
Spare 2
input
input
input
input
0
1
2
3
4
5
6
7
8
9
A
b
C
d
E
F
[Outdoor unit – Capacity setting display] (Request code : "70")
Data display
Capacity
10
50
9
35
11
60
14
71
20
100
25
125
28
140
40
200
50
250
[Outdoor unit – Setting information] (Request code : "71")
Data display
Setting information
1
Setting information
2
0 0
Setting information
1
Display
Defrost mode
0
Standard
1
For high humidity
Setting information
2
Display
Single-/
Heat pump/
3-phase
cooling only
0
Single-phase
Heat pump
1
Cooling only
2
3-phase
Heat pump
3
Cooling only
Setting content
Display
Setting value
0
1
50%
2
75%
0%
3
100%
Содержание PUZ-ZM60VHA2
Страница 21: ...21 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 6 OUTLINES AND DIMENSIONS 1 2 1 1 2 Unit mm ...
Страница 23: ...23 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 7 WIRING DIAGRAM ...
Страница 24: ...24 OCH771 PUZ ZM100VKA2 ET ER UK ...
Страница 25: ...25 OCH771 PUZ ZM125VKA2 ET ER UK PUZ ZM140VKA2 ET ER UK ...
Страница 26: ...26 OCH771 PUZ ZM100YKA2 ET ER UK PUZ ZM125YKA2 ET ER UK PUZ ZM140YKA2 ET ER UK ...
Страница 27: ...27 OCH771 PUZ ZM200YKA2 UK PUZ ZM250YKA2 UK ...