122
OCH771
Main
menu
Setting and display items
Setting details
Initial
setting
Basic
setting
Main/Sub
When connecting 2 remote controllers, one of them needs to be designated as
a sub controller.
Clock
Use to set the current time.
Daylight
saving time
Set the daylight saving time.
Administrator
password
The administrator password is required to make the settings for the following
items.
• Timer setting • Energy saving setting • Weekly timer setting
• Restriction setting • Outdoor unit silent mode setting • Night set back
Display
setting
Main display
Use to switch between ˝Full˝ and
˝
Basic˝ modes for the Main display, and use
to change the background colors of the display to black.
Display details
Make the settings for the remote controller related items as necessary.
Clock:
The initial settings are ˝Yes˝ and ˝24h˝ format.
Temperature:
Set either Celsius (°C) or Fahrenheit (°F).
Room temp.:
Set Show or Hide.
Auto mode:
Set Auto mode display or Only Auto display.
Contrast
•
Bright-
ness
Use to adjust screen contrast and brightness.
Language selection Use to select the desired language.
Operation
setting
Auto mode
Whether or not to use Auto mode can be selected by using the button.
This setting is valid only when indoor units with Auto mode function are
connected.
Mainte-
nance
Error information
Use to check error information when an error occurs.
• Check code, error source, refrigerant address, model name, manufacturing
number, contact information (dealer's phone number) can be displayed.
(The model name, manufacturing number, and contact information need to be
registered in advance to be displayed.)
Filter information
Use to check the filter status.
• The filter sign can be reset.
Cleaning Auto descending
panel
Use to lift and lower the auto descending panel (Optional parts).
Service
Test run
Select ˝Test run˝ from the Service menu to bring up the Test run menu.
• Test run • Drain pump test run
Input maintenance info.
Select ˝Input maintenance Info.˝ from the Service menu to bring up the
Maintenance information screen.
The following settings can be made from the Maintenance Information screen.
• Model name input • Serial No. input • Dealer information input • Initialize
maintenance info.
Settings Function setting Make the settings for the indoor unit functions via the remote controller as
necessary.
Check
Error history
Display the error history and execute
˝
delete error history
˝
.
Diagnosis
Self check:
Error history of each unit can be checked via the remote controller.
Remote controller check:
When the remote controller does not work properly, use
the remote controller checking function to troubleshoot the problem.
Smooth mainte-
nance *
3
Use to display the maintenance data of indoor/outdoor units.
Request code *
3
Use to check operation data such as thermistor temperature and error
information.
Others
Maintenance
password
Use to change the maintenance password.
Initialize remote
controller
Use to initialize the remote controller to the factory shipment status.
Remote control-
ler information
Use to display the remote controller model name, software version, and serial
number.
*
3
This function is available only when certain outdoor units are connected.
Содержание PUZ-ZM60VHA2
Страница 21: ...21 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 6 OUTLINES AND DIMENSIONS 1 2 1 1 2 Unit mm ...
Страница 23: ...23 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 7 WIRING DIAGRAM ...
Страница 24: ...24 OCH771 PUZ ZM100VKA2 ET ER UK ...
Страница 25: ...25 OCH771 PUZ ZM125VKA2 ET ER UK PUZ ZM140VKA2 ET ER UK ...
Страница 26: ...26 OCH771 PUZ ZM100YKA2 ET ER UK PUZ ZM125YKA2 ET ER UK PUZ ZM140YKA2 ET ER UK ...
Страница 27: ...27 OCH771 PUZ ZM200YKA2 UK PUZ ZM250YKA2 UK ...